Maximum Working Pressure Tables - Alloy 400 Annealed Seamless Tube
(Nickel, Copper / ASTM B-165 or Equivalent)


Maximum Allowable Working Pressure (PSI) For Fractional Sizes

Tubing ODWall Thickness (Inches)
.010.012.016.020.028.035.049.065.083.095.109.120
1/166,4227,87210,76813,484        
1/8   6,4229,32511,823      
3/16   4,0815,9357,63011,005     
1/4    4,3055,5188,05310,946    
3/8     3,5305,1077,029    
1/2     2,5953,7215,0786,699   
5/8     2,0512,9273,9705,2006,056  
3/4     1,6962,4123,2594,2494,9335,7556,422
7/8     1,4462,0512,7643,5924,1614,8425,391
1     5,0407,1409,59512,44514,39016,71518,585
Factor of Safety = 4, considering tensile strength to be 70,000 PSI at room temperature.

Maximum Allowable Working Pressure (Bar) For Metric Sizes

Tubing ODWall Thickness (Inches)
0.50.60.70.81.01.21.51.61.82.02.22.53.0
3464567672775965        
4335411491567723873       
6  310360464567723775     
8  227262335411528567     
10   206262320411442     
12   169215262335360411464   
14    182222282303345389433500612
16    158192244262298335372430528
18    140169215230262294326377464
22    113137173186211236262301369
25    99120152162184206228262320
Factor of Safety = 4, considering tensile strength to be 482.6 MPa at room temperature.